Home > Socket Error > Windows Sockets Error 10061

Windows Sockets Error 10061

Contents

Add comment Created on Feb 3, 2010 9:01:16 AM by Daniel Zobel [Paessler Support] Last change on Sep 9, 2015 1:04:29 PM by Gerald Schoch [Paessler Support] Permalink Please log in WSAEAFNOSUPPORT 10047 Address family not supported by protocol family. send() or sendto(): out of buffer space, so try again later or wait until FD_WRITE notification (WSAAsyncSelect()) or select() writefds is set. WinSock description: Same as Berkeley, and then some. news

WinSock functions: connect(), FD_CONNECT Additional functions: Any function that does I/O on the network could generate this error, and the WSAAsyncSelect() events FD_OOB, FD_READ, FD_WRITE. You see the settings the Enterprise Console uses to connect to the PRTG Web Server. The remote server may be temporarily or permanently inaccessible (try again later). WSANO_RECOVERY 11003 This is a nonrecoverable error.

Socket Error 10054

WinSock functions: With a datastream socket: connect() and FD_CONNECT WSAAsyncelect() notification message. If there is more than one Winsock DLL on your system, be sure the first one in the path is appropriate for the network subsystem currently loaded. You cannot mix and match (WINSOCK DLLs must be supplied by the same vendor that provided your underlying protocol stack). WinSock description: Same as Berkeley, and then some.

A system call that should never fail has failed. Try pinging the address. (See Troubleshooting Tips for details.) If you are using a router, verify the router is up and running (check by pinging it and then ping an address If the hostname resolution uses a local host table, it's possible you resolved to an obsolete address. Socket Error 10061 Connection Refused WSA_QOS_BAD_OBJECT 11013 QoS bad object.

I am using Windows Xp SP2!!! WSA_QOS_EPSFILTERSPEC 11028 Invalid QoS provider-specific filterspec. It may also indicate you are not closing the applications properly. WSAEHOSTDOWN 10064 Host is down.

If you used a hostname, did it resolve to the correct address? Winsock Error 10061 This error often occurs when you try to connect in PASV mode to a server that prefers PORT for data connections. The Windows function is indicating a problem with one or more parameters. WSAEAFNOSUPPORT (10047) Address family not supported by protocol family.

  1. The values for WSANO_DATA and WSANO_ADDRESS (11004) are duplicates, so we don't count one of them.
  2. An unrecognized object was found in the QoS provider-specific buffer.
  3. WinSock description: No equivalent.
  4. WinSock functions: connect(), sendto(), FD_CONNECT Additional functions: Any function that does network I/O: recv(), recvfrom(), send(), FD_READ, FD_WRITE See also: WSAEHOSTUNREACH WSAENOBUFS (10055) No buffer space available.
  5. Disclaimer: This website is not affiliated with Wikipedia and should not be confused with the website of Wikipedia, which can be found at Wikipedia.org.
  6. Under MS-DOS versions 3.0 and later, EACCES may also indicate a locking or sharing violation.
  7. WSATRY_AGAIN 11002 Nonauthoritative host not found.
  8. Use socket state in an application and/or handle this error gracefully as a non-fatal error.
  9. WSA_QOS_EOBJLENGTH 11022 Invalid QoS object length.

Socket Error Codes Linux

WinSock functions: WSAEFAULT (10014) Bad address. check that copies what it can into your buffer) and fails the function. Socket Error 10054 In the Web Server tab, you can view the section Select IP Address for PRTG's Web Server denoting the IPs that are allowed to establish a connection to the Web Server. Socket Error 10053 WSAEOPNOTSUPP (10045) Operation not supported.

For inet_addr(), this could mean the content of the buffer passed or the buffer itself is invalid. navigate to this website Any of the WinSock name resolution functions can fail with this error. WinSock description: Same as Berkeley. you're trying to share a socket between tasks). Socket Error 10054 Connection Reset By Peer

There a couple of users on the LAN that I want to limit download limit, but I can't seem to connect to any pc on the network, I'm getting the same WinSock description: Same as Berkeley. It should be installed on a computer which you want to control. More about the author WSASYSNOTREADY 10091 Network subsystem is unavailable.

There can be several reasons for this. Socket Error 11004 An invalid or unrecognized service type was found in the QoS flowspec. It is a nonfatal error, and the operation should be retried later.

The WSAAsyncSelect() FD_WRITE event is specifically designed to notify an application after a WSAEWOULDBLOCK error when buffer space is available again so send() or sendto() should succeed.

Rumba attempts to connect to that address, but the Server application is only bound to the IPv4 address, so there is no response to the connect attempt. An invalid policy object was found in the QoS provider-specific buffer. NFS is "network-related" in the strictest sense, but the Network File System protocol is an application protocol (i.e. Socket Error 10061 Ppsspp WinSock description: Same as Berkeley.

WSA_QOS_POLICY_FAILURE 11011 QoS policy failure. For example, you shouldn't necessarily expect to be able to use NS addresses with ARPA Internet protocols. WinSock description: Unlike Berkeley Sockets, in WinSock WSAEALREADY means that the asynchronous operation you attempted to cancel has already been canceled. click site Although the specification doesn't list an error for a function, it does allow for it.

Berkeley description: No equivalent in 4.3 BSD or compatible operating systems. WSATYPE_NOT_FOUND 10109 Class type not found. Developer suggestion: The simple suggestion is "don't do that." No matter what value you use for the "how" parameter to the shutdown() function, you cannot send afterwards. WinSock functions: Additional functions: any function that takes a socket (or file handle) as an input parameter See also: WSAENOTSOCK WSAECONNABORTED (10053) Software caused connection abort.